Strict Standards: Redefining already defined constructor for class wpdb in /home/pssmdeva/public_html/admin/classes/Db.class.php on line 361

Warning: session_start(): Cannot send session cookie - headers already sent by (output started at /home/pssmdeva/public_html/admin/classes/Db.class.php:361) in /home/pssmdeva/public_html/includes/authArea.php on line 23

Warning: session_start(): Cannot send session cache limiter - headers already sent (output started at /home/pssmdeva/public_html/admin/classes/Db.class.php:361) in /home/pssmdeva/public_html/includes/authArea.php on line 23

Warning: Cannot modify header information - headers already sent by (output started at /home/pssmdeva/public_html/admin/classes/Db.class.php:361) in /home/pssmdeva/public_html/includes/controller.class.php on line 175
Verificare electrica periodica P.R.A.M. Hosting City a Hosting Category Flat Bootstrap responsive Website Template | Home :: w3layouts

Verificare electrica P.R.A.M.

Verificare electrica P.R.A.M.

Verificarile PRAM reprezinta verificarea prizelor de impamantare si paratrasnetelor si are ca scop:
• Prevenirea electrocutarii personalului care utilizeaza instalatia electrica si echipamentul de lucru;
• Prevenirea incendierii cladirilor si prevenirea distrugerii aparaturii electrice si electronice;
• Verificare continuitatii nulului de protectie.

     Verificarea si masurarea se efectueaza conform HG 1146/2006 Anexa 1 pct. 3.3.16.2.(“Instalatiile sau echipamentele de munca electrice trebuie sa fie verificate la receptie,inainte de punerea in functiune si apoi periodic in exploatare,precum si dupa fiecare reparatie sau modificare, fiind interzisa punerea sub tensiune a instalatiei,utilajului sau echipamentului care nu a corespuns la una dintre aceste verificari”).

Verificarea PRAM reprezinta masurarea rezistentei de dispersie a instalatiei de pamantare si paratrasnetului cu aparat special pentru acest scop. Aparatul este verificat periodic de metrologie autorizata.
Periodicitatea verificarii PRAM este prevazuta de legislaţia şi/sau cu practicile naţionale dupa cum urmeaza :

- NTE 01 116/2001-Norma tehnica energetica privind incercarile si masuratorile la echipamente si instalatii electrice:

     20.1. Măsurarea rezistenţei de dispersie
     Condiţii de execuţie a probei
Verificarea va fi efectuată numai de către personal instruit pentru astfel de măsurări.
     Momentul efectuării probei
B. Instalaţii de joasă tensiune,cu excepţia stâlpilor, o dată la 2 ani, iar în exploatările subterane, de două ori pe an pentru cele locale şi o dată pe an pentru reţeaua generală.
În mediile foarte periculoase - o dată pe an.

     20.2. Verificarea gradului de corodare a instalaţiilor de legare la pământ
     Momentul efectuării probelor
După 10 ani de la îngropare şi ulterior cel puţin o dată la 5 ani
     - Ordin nr. 108 din 1 August 2001/Ministerul de Interne/pentru aprobarea DGPSI 004-
Dispozitii generale privind reducerea riscurilor de incendiu generate de încărcări
electrostatice:
     Art. 94. Masurarea rezistentei de dispersie pentru instalatia de legare la pamant se face:
a) in instalatii subterane si in instalatii locale de legare la pamant,cel putin de doua ori pe an;
b) la retelele generale de legare la pamant, cel putin o data pe an

     Verificarea Periodica a Instalatiilor Electrice trebuie executata deoarece prin aceasta putem evita situatii neplacute cum ar fi de exemplu: incendii, electrocutari, deconectari in alimentarea cu energie.

     Verificarile periodice PRAM pot constitui obiective de control ale institutiilor abilitate ale statului in cadrul firmei d-voastra, cum ar fi :Inspectoratul Teritorial de Munca,Protectia Consumatorului si Inspectoratul pentru Situatii de Urgenta.

     Verificarea periodica a instalatiilor electrice este necesara, deoarece toate instalatiile se deterioreaza din cauza unui numar de factori cum ar fi incarcare excesiva a circuitelor, uzura echipamentelor, coroziune , imbatrinirea izolatiilor.
In consecinta legislatia prevede ca instalatiile electrice trebuie sa fie mentinute intr-o stare corespunzatoare de siguranta, iar pentru aceasta ele trebuie sa fie inspectate si testate periodic.

     Aceste verificari cuprind o serie de masuratori cum sunt: rezistenta de izolatie, impedanta de bucla, curentul de scurt circuit, rezistenta de dispersie a prizelor de pamant, continuitatea centurii de impamantare, verificarea aparatelor de protectie inclusiv a disjunctoarelor diferentiale.

     In urma analizarii acestor masuratori se emit Rapoartele de incercari pentru instalatia verificata, rapoarte care certifica starea instalatiilor si echipamentelor electrice.

     Toate acestea sunt executate de personal cu indelungata experienta in domeniu si care dispune de o dotare de ultima generatie conforma cu standardele si normativele in vigoare.

     Va putem oferi acest serviciu dispunind de oameni cu calificare si experienta PRAM, cu dotare de aparatura de testare conforma cu legislatia actuala.

     In urma verificarii PRAM se intocmeste un Raport de verificare/incercare care cuprinde:

• Conditiile de masurare;
• Tipul aparatului;
• Executantul si locul masurarii.

 In cazul in care valorile masurate nu corespund normelor, instalatia prezinta pericol de electrocutare,
iar paratrasnetul nu mai prezinta siguranta impotriva incendierii in caz de trasnet. Pentru evitarea acestor
evenimente nedorite, putem remedia rapid problemele si executam reverificare PRAM pentru siguranta.

Executia lucrarilor se efectueaza in baza unui contract de prestari servicii.


Conform legii nicio firma nu are voie sa proiecteze sau execute instalatii electrice fara a avea un atestat emis de ANRE, autoritatea in domeniu, asadar daca vreti sa nu aveti griji ca ati pierdut afacerea in care ati investit, va oferim posibilitatea la un pret acceptabil sa intrati in legalitate.

In vederea finalizarii consultantei pe care vi-o acordam in vederea obtinerii de catre firma dvs a atestatului ANRE, trebuie sa realizam urmatorii pasi :

    Semnarea contractului de consultanta
    Plata avansului conform contract
    Intocmim un OPIS cu toate CERINTELE necesare obtinerii atestatului ANRE
    Analizam STRUCTURA de personal calificata necesara si suficienta
    Analizam DOTAREA tehnico-materiala necesara si suficienta
    Verificam Codul CAEN corespunzator activitatii de instalatii electrice in constructii + proiectare.
    Intocmire SMC (Sistemul de Management al Calitatii)- ISO 9001:2001

        MMC (Manualul de Management al Calitatii)
        Proceduri de Sistem
        Proceduri Operationale
        Instructiuni  Tehnice de Executie

    Semnarea documentelor din dosar de catre reprezentantii firmei dvs
    Expedierea dosarului

Dupa incheierea contractului veti obtine informatiile despre documentele de care aveti nevoie si dotarea minima necesara. Investitia pentru atestare nu este mare in comparatie cu riscul de a lucra ilegal, chiar daca platiti taxe si impozite.
Solicitati in pagina Contact un tarif pentru consultanta.

Serviciile noastre

Servicii - SSM

Notiunea de securitate si sanatate in munca reprezinta noua denumirea a celei de protectia muncii

Servicii - Situatii de Urgenta

Documentatia pe linie de prevenire si stingere a incendiilor si Asistenta periodica lunara pe linie

Servicii – Certificari ISO

Echipa profesionista de lead auditori in colaboarre cu organism de certificare acreditat RENAR va of

Verificare electrica P.R.A.M.

Verificarea PRAM reprezinta masurarea rezistentei de dispersie a instalatiei de pamantare si paratra

Consultanta Atestare ANRE

RAISA CONSULTING ofera servicii de consultanta in vederea obtinerii atestatului ANRE pentru orice ti

Acte si diplome

Avem experienta de peste 10 ani in domeniul consultantei si securitate sanatate in munca si situatii

Cursuri

Cursul se adresează tuturor celor interesaţi în actualizarea cunoştinţelor privind legislaţia

Coordonare SSM

Atributiile Coordonatorul în materie de securitate si sanatate pe durata realizarii lucrarii privin